TPH Series · Pump Systems

TPH Vertical Multistage Hydrophore Pumps

Vertical shaft, multistage hydrophore (booster) pump sets for pressurized water supply in buildings and industrial facilities. Available as 1, 2 or 3 pump configurations.

Series: TPH Series | Category: Pump Systems | Mode: Catalog

Desan Engineering TPH series hydrophores are designed for liquids that do not contain corrosive substances or large solid particles.

Vertical shaft, multi-stage, closed impeller pumps with Noryl impellers. Impeller balance holes are dynamically balanced to minimize axial loads. Discharge flange is below the motor side; suction flange is on the lower casing — compact footprint for mechanical rooms.

Package features

  • Standard manufacture as single, dual or triple pump units by required flow
  • Single-pump sets: phase protection / sequencing relay (FKS) and water level float switch
  • Mechanical seal standard; alternate seal brands/types and materials on request
  • Typical materials: suction casing GGG25, discharge casing GG25, shaft AISI 304, impeller Noryl
Parameter Value
Series range TPH 100 / 200 / 300 / 400 / 500 / 600 / 700
Configuration 1, 2 or 3 pump booster sets
Impeller Noryl
Shaft AISI 304
Suction casing GGG25 cast iron
Discharge casing GG25 cast iron
Shaft sealing Mechanical seal (standard)
Controls (1-pump) FKS phase/sequencing + float switch
Layout Vertical multistage, space-saving

Example material set (TPH 200-8 class): suction GGG25, discharge GG25, impeller Noryl, shaft AISI 304.

Cross-section drawing — vertical multistage construction.

Cross-section drawing — vertical multistage construction.

Dimensional drawing — set layout and connections.

Dimensional drawing — set layout and connections.

Full curves, BOM lists and dimension tables are in the technical catalog (PDF).

Booster packages
Sets combine pump type, motor kW (examples from ~5.5 to 18.5 kW at 2,900 rpm), membrane tank volume (e.g. 500 / 750 / 1,000 L) and 1× / 2× / 3× pump arrangements.

Operating curves show staged contribution of 1st, 2nd and 3rd pumps across the Q–H envelope.

Share required flow, pressure, number of pumps and tank preference for package selection.